APPLICATION
- The DCD-135/-190 fixed temperature/rate-of-rise heat detector are suited for installation where high heat output fires are expected or in areas where ambient conditions would not allow use of other detection methods.
- Heat detectors are intended for protection of property.
- Do not rely on heat detectors for life safety protection. Where life safety is a concern, smoke detectors must also be used.
- A UL listed fire alarm panel must electronically supervise the DCD-135/-190 heat detectors.
- All NS conventional devices are mechanically compatible with Hochiki America HSB, HSC and YBA type bases.
- Please check individual panel listings for appropriate listed bases.
STANDARD FEATURES
- Fully electronic operation
- Power/alarm LED’s confirm detector status
- Compatible with Hochiki SLR-24V and SIJ-24 detectors and their bases
- Choice of fixed temperature/rate-of-rise 135°F or 190°F heat detector
- UL Listed spacing up to 60′ by 60′
- 2 or 4 wire base compatibility, relay bases available
- Highly stable operation, RF/Transient protection
- Low standby current, 35µA nominal
- Two built-in power/alarm LED’s for 360° viewing
OPERATION
- The DCD-135/-190 fixed temperature/rate-of-rise heat detectors are suited to detect in the presence of slow or fast rising temperatures due to burning combustibles.
- The construction of these models incorporate a thermistor heat element protected from damage by the built-in, durable plastic guard.
- These electronic heat detectors incorporate two power/alarm LED’s for 360° indication of status. In standby condition the power LED’s flash Green.
- In an alarm condition the LED’s latch on Red.
- The DCD-135/-190 electronic heat detection circuitry performs the same function as a Mechanical Device but with Electronic Precision.
- If the heat rise is less than 12°/minute the DCD will not alarm until it reaches its alarm temperature (135° or 190° ± 7.5°F).
- If the heat rise is greater than 12°/minute the DCD will alarm immediately giving an early warning signal and latching the Red alarm LED’s on.
SPECIFICATIONS
- Response Temperature: 135° ± 7.5°F / 190° ± 7.5°F
- Rated Voltage: 17.7 – 30.0 VDC
- Working Voltage: 15.0 – 33.0 VDC
- Maximum Voltage: 42 VDC
- Supervisory Current: 40µA @ 24 VDC
- Surge Current: 160µA max @ 24 VDC
- Alarm Current: 150mA max. @ 24 VDC
- Ambient Temperature: 32°F to 120°F(0°C to 49°C)
- Contact Rating N/O Contacts:150mA max. @ 24 V
- Color & Case Material Bone PC/ABS blend
- Mounting Refer to the NS Conventional Detector Base Data Sheet